Roofing Inspection Checklist

An interactive working log for controlling roofing works, watertightness, and project handover.

Collection · ChecklistsAuthor · RAMERKStatus · Working EditionLanguage · EN / RU
Open the BookScroll to begin
Inspection Record

Project Information

○ Not checked◐ Requires attention● Completed
Section 001

Before Work Begins

Roofing works begin with the design, safe access, and an understanding of the water path.

Approved roof design and details are availableIncluding junctions, penetrations and drainage
Existing condition is documentedPhotos and defects
Temporary weather protection is plannedOpen roof risk is controlled
Fall protection and access are readySafe inspection is possible
Weather forecast is acceptableWind, rain and temperature limits
Section 002

Materials & Storage

Roofing materials retain their properties only when correctly identified and stored.

Materials match design and systemType, class, thickness and compatibility
Certificates and DoP are availableWhere applicable
Rolls, membranes and insulation are dryNo damaged packaging
Fasteners and accessories are correctMaterial, coating, size and quantity
Manufacturer installation instructions are on siteCurrent edition
Section 003

Substrate & Vapour Control

The underlying layers determine the durability of the entire roof.

Substrate is sound, dry and cleanNo sharp projections or weak areas
Falls are formed as designedNo unintended backfalls
Vapour barrier is continuousJoints, upstands and penetrations sealed
Air leakage routes are closedCritical junctions inspected
Hidden conditions are photographedBefore covering
Section 004

Thermal Insulation

Thermal insulation is installed without gaps or conditions that allow water to accumulate.

Correct type and thicknessMatches design
Boards are tightly fittedNo open joints
Layers are staggered where specifiedJoints offset
Tapered insulation follows drainage planFalls maintained
Wet or damaged insulation is rejectedNot covered
Section 005

Waterproofing

Waterproofing must be a continuous system, not a collection of separate sheets.

Membrane type and layer build-up are correctAccording to design
Seams are formed and testedMethod suitable for membrane
Upstands reach required heightAt parapets and penetrations
Corners and changes of plane are reinforcedNo fishmouths or tension points
Mechanical fastening / bonding is correctPattern and adhesion recorded
Section 006

Drainage

Water must have a continuous and clearly defined path off the roof.

Roof outlets are correctly locatedAt low points
Falls lead to outletsNo backfalls
Overflow provisions are presentWhere required by design
Outlets are securely sealedMembrane integration complete
Strainers and access are providedMaintenance possible
Ponding areas are recorded and resolvedBefore handover
Section 007

Flashings & Penetrations

Most leaks begin in the details.

Parapet and edge flashings are completeSecure and weather-tight
Penetrations use approved detailsPipes, ducts, supports and cables
Movement is accommodatedNo rigid tearing points
Metal joints and laps are correctDirection and allowance for expansion
Sealants are compatible and properly tooledCorrect backing and dimensions
Section 008

Roof Safety & Equipment

The roof must remain safe and maintainable after the works are completed.

Walkways and access routes are installedWhere required
Anchors and safety systems are documentedCertificates and locations
Equipment supports do not compromise waterproofingLoads and details checked
Snow guards and edge systems are completeWhere required
Maintenance access to outlets is clearNo obstruction
Section 009

Testing & Handover

The roof is accepted after the details, water path, and documentation have been checked.

Seams and details are inspected100% visual inspection
Water / integrity testing is completed where specifiedMethod and result recorded
Roof is clean and free of construction debrisOutlets clear
Defects are listed and correctedClosure verified
As-built photos and drawings are completeIncluding hidden layers
Maintenance instructions and warranties are deliveredClient archive complete